Model
No.
|
RATE
METER/TOTALIZER, BATCH CONTROLLER, CLOCK |
PRICE
|
|
INF7
|
6-digit
(999,999) meter which is user configurable as a rate meter
and counter with or without integral square root extraction,
batch controller or real-time clock. NEMA-4 front bezel,
5 open-collector outputs, programmable decimal point, and
non-volatile memory are all standard. Calibration and scaling
is via the front pushbuttons or serial communications port.
|
$395.00
|
|
OPTIONS
|
DESCRIPTION |
PRICE
|
|
POWER
AND LED COLOR
|
|
0
|
Designates
115 V ac power and red LED display |
N/C
|
|
1
|
Designates 230 V ac power and red LED display |
N/C
|
|
2
|
Designates
115 V ac power and green LED display |
N/C
|
|
3
|
Designates
230 V ac power and green LED display |
N/C
|
|
INPUT(S)
|
|
0
|
Non-isolated
inputs: TTL/5 V CMOS logic, NPN open-collector pulse
sensor, or contact closure. Factory default calibration
is 0-10,000 Hz = 0-10,000 on display
|
N/C
|
|
1
|
Isolated
input: magnetic pick-ups with signals from 120 mV p-p
10-60 V rms, direct connection to NPN, PNP or NAMUR sensors.
Includes electrically floating, regulated sensor excitation
supplies rated 12V @ 70 mA or 8.2 V with 1 kohm source impedence.
Factory default calibration is 0-10,000 Hz = 0-10,000.(P7A1) |
$75.00
|
|
2
|
Isolated
Analog to Frequency converter input: 0-1 mA, 4-20 mA,
0-5 V, 1-5V or 0-10 V dc. Factory default setup is 4-20
mA = 0 to 10,000 on display (P7A5A) |
$195.00
|
|
BCD
AND CONTROL OUTPUT(S)
|
|
0
|
Four
optically isolated open-collector outputs |
N/C
|
|
1
|
Isolated parallel BCD output (BCD1) |
$110.00
|
|
2
|
Isolated
dual 7 A relays (REL1) |
$75.00
|
|
3
|
Isolated
dual 7 amp and dual 1 amp relays* (REL4) |
$175.00
|
| *
Not available with dc power options 4 and 5 above. |
|
ANALOG
OUTPUT
|
|
0
|
No
analog output |
N/C
|
|
1
|
Isolated
analog output (0-20 mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V (AN03) |
$110.00
|
|
SERIAL
OUTPUTS
|
|
0
|
No
serial output |
N/C
|
|
1
|
Isolated
RS-232 serial output* (RS20) |
$110.00
|
|
2
|
Isolated
RS-485 serial addressable output* (RS40) |
$110.00
|
| *Includes
6' cable with RJ telephone jack connectors. |
|
OPERATING
MODES - Factory default setup is for standard rate/totalizer
|
|
R
|
Rate
totalize (factory default setting)
|
N/C
|
|
Q
|
Rate/totalize
with integral square root extraction |
N/C
|
|
B
|
Batch
controller |
N/C
|
|
C
|
Clock |
N/C
|
| ADD-ON
OPTIONS |
|
FS
|
Special
calibration configuration |
$45.00
|
|
BL
|
Blank
Lens |
$15.00
|
| ACCESSORIES |
|
9SC2
|
9-pin
serial connector for RS-232 |
$30.00
|
|
9SC4
|
9-pin
serial connector for RS-485 |
$30.00
|
|
25SC2
|
25-pin
serial connector for RS-232 |
$30.00
|
|
25SC4
|
25-pin
serial connector for RS-485 |
$30.00
|