RTD
TEMPERATURE METER / CONTROLLER
PANEL METERS/CONTROLLERS
The unparalled accuracy of the NEWPORT®
Electronics INFINITY® signal conditioning
is available in an economical series of Panel Meter/Controllers.
The NEWPORT INFINITY® "C" series
of meter/controllers feature a four digital display plus
optional dual 5 amp Form C relays and a choice of isolated
or non-isolated analog output. The scalable 0-10 Vdc,
0-20mA, or 4-20 mA analog output can be used a retransmission
of the display value or as a proportional control output
as required. The microprocessor based INFINITY®
"C" series includes instruments for Process
(DC voltage and current) Strain Gage, Thermocouple, RTD,
Dual/Differential Thermocouple, Dual/Differential RTD,
pH, ORP.
The INFCRP
accepts 3-wire 100 ohm platinum RTD inputs (alpha = 0.00385)
and has an accuracy of ±0.5°C. Relay models offer the choice
of linear or proportional analog output.
SPECIFICATIONS
Input: RTD 100ohm Pt (0.00385 curves) 2, 3 and
4 wire selectable
Relay Outputs: 2 Form C (SPDT) relays, rated
5 Amp 250 Vac; programmable for active high/low alarms
with latching/non-latching relays. The INFCRP
includes an NPN open-collector transistor output for
time proportional setpoint 1.
Relay Hysteresis: programmable from 0 to 9999
Accuracy: ±0.50°C after 30 min. warm-up
Analog Output: Scalable 0-10 Vdc or 4-20 mA
Temperature Coefficient: ±50 PPM/°C
Read Rate: 3/sec
Step Response: 2 seconds
Isolation: Dielectric strength to 2500V transient
per 3mm spacing based on EN 61010 for 260 Vrms or DC.
NMR: 60 dB
CMR: 120 dB
Input Resistance: 100 Mohms
Operating Temperature: 0 to 50°C (32 to 122°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Dimensions: 48 H x 96 W x 152 D mm (1.89" x 3.78"
x 6.0")
Panel Cutout: 45 x 92 W mm (1.772" x 3.622")
AC
Power Unit:
Power: 115 Vac or 230 Vac ±10%; 50-60 Hz, 8 watts
max.
DC Power Unit:
Power: 10-32 Vdc or 26-56 Vdc; 7 watts max.
|
RTD800
RTD
Precision Probes
|
|
Model
|
Input
Type
|
Range
|
|
INFCRP
|
Pt
RTD, 100ohm 385 curve 2, 3, 4-wire
|
-200
to 850°C
|
Power
and Display Options
|
Order
Code
|
Power
|
Display
|
Add'l
Price
|
|
0
|
115
Vac
|
red
|
N/C
|
|
1
|
230
Vac
|
red
|
N/C
|
|
2
|
115
Vac
|
green
|
N/C
|
|
3
|
230
Vac
|
green
|
N/C
|
|
4
|
10-32
Vdc
|
red
|
$95
|
|
5
|
10-32
Vdc
|
green
|
$95
|
|
6
|
26-56
Vdc
|
red
|
$120
|
|
7
|
26-56
Vdc
|
green
|
$120
|
To
Order (Specify
Model No.) Prices Shown in U.S. Dollars
|
Model
No.
|
Description
|
Price
|
|
|
Time
proportional relay with manual tune and analog output |
$395
|
Each
unit supplied with complete operator's manual.
† Specify order code from Power and Display Options chart.
Ordering Example: INFCRP-011A,
RTD thermometer with dual relays and analog output, 115
Vac power, red LED display, $395.
|